Talk to us
An electrical substation at sunrise

Every MWh audit-ready, from fuel to substation.

We prepare the emissions, efficiency and impact data regulators, PROPER and offtakers ask for at every phase of coal, gas, geothermal and solar plants, then bring it together on Ailesh+.

Power plants are now judged unit by unit.

Emission caps, stack data and efficiency evidence are now required for every unit. Data recorded properly from commissioning gets reused for carbon quotas, PROPER and lender reporting.

Risk

Power-sector carbon trading now extends to captive coal plants and gas-fired plants. A unit that exceeds its cap has to close the gap by buying allowances or using offsets.

146 → 563 installations in carbon trading, from 2024 to the first phase 2 cycle.

According to ICAP, 2026; The Jakarta Post, 2026

Opportunity

Most new capacity in PLN's electricity supply plan (RUPTL) comes from new and renewable energy. A well-documented site, substation and emissions record become assets for new projects and transition finance.

42.6 of 69.5 GW of new capacity in the 2025–2034 RUPTL is new and renewable.

According to the Ministry of Energy and Mineral Resources, 2025; PV Tech, 2025

Priority

Set a tCO2e per MWh baseline for each unit, make sure CEMS sends valid data, then build co-firing and coal ash plans that can be audited. That data fills carbon quota, PROPER and PSPK reporting at once.

  • Power-sector carbon trading (Energy Ministry Regulation 16/2022 and Presidential Regulation 110/2025)

    phase 2 runs 2025–2027

    Coverage now extends to captive coal and gas plants. Energy-sector rules under Presidential Regulation 110/2025 were still in draft as of September 2026.

    According to ICAP, 2026; Katadata, 2026

  • Power-sector transition roadmap (Energy Ministry Regulation 10/2025)

    in force since 15 Apr 2025

    New coal plants are banned except under listed exemptions, and early retirement is assessed on age, utilisation, emissions and funding.

    According to Pasal.id; Bisnis.com, 2025

  • CEMS and SISPEK (Environment and Forestry Ministry Regulations 15/2019 and 13/2021)

    in force

    Coal units of 25 MW and above need continuous emission monitoring (CEMS), sending hourly data to the ministry's SISPEK system and reporting every three months.

    According to the BPK legal database

From site to early retirement, one record.

The emissions intensity behind a unit's carbon quota starts forming when the technology is chosen. Pick your phase to see what needs to be ready.

Phase 1: Pick the site once the substation can take the power.

A plant only gets built if it is in the RUPTL and the grid can carry its output. The technology chosen here sets the unit's carbon quota for decades.

What needs to be ready

    • 1.1 RUPTL, substation and land status

      Confirm the project is listed in the RUPTL, the target substation has capacity, and the site sits outside the state forest estate or holds a forest-use approval.

    • 1.2 Nature and community baseline

      Survey montane forest at planned wellpads, marine life at the planned intake, and fishing grounds and customary land before public consultation.

    • 1.3 Quota scenario per technology

      Cost the carbon quota for each technology option before the decision is locked. New coal plants are only allowed under exemptions, and such units may run until 2050 at the latest.

      According to Energy Ministry Regulation 10/2025

Phase 2: Emission limits are fixed in the design drawings.

Emission controls, cooling and co-firing readiness are decided before the EPC contractor is chosen. Changing them once the unit runs means a costly retrofit.

What needs to be ready

    • 2.1 AMDAL and technical approvals in parallel

      One environmental impact assessment (AMDAL) covers the boiler, emission controls, intake, outfall, jetty and transmission line.

      new coal units capped at 200 mg/Nm³ for SO2 and NOx

      According to Environment and Forestry Ministry Regulation 15/2019

    • 2.2 Efficiency and co-firing from the design stage

      Fix the heat rate, biomass-ready mills and feeders, heat recovery at combined-cycle plants and the use of geothermal brine.

    • 2.3 A coal ash plan from the start

      Coal ash (FABA) is classed as non-hazardous, but using it still needs approval. Plan silos, leaching (TCLP) tests and cement-plant partnerships before the unit starts.

      According to Government Regulation 22/2021

Phase 3: Your PROPER record starts with the first pile.

Dust, sediment and community complaints peak in the construction year, and those reports are read at your first PROPER assessment. At a geothermal plant, drilling mud and H2S from test wells are obligations before the turbine arrives.

What needs to be ready

    • 3.1 Construction monitoring

      Track dust, noise and sediment in the intake canal and pipe trenches every semester, then report them through the SIMPEL system.

    • 3.2 Coast and forest around the site

      Monitor seawater during jetty dredging, plant compensatory mangroves and reinject brine from test wells.

    • 3.3 Local hiring and grievances

      Record the local-hire share, fisher compensation and every community complaint from day one, including those involving the EPC contractor.

Phase 4: Your first year sets the unit's quota benchmark.

Emissions intensity, heat rate and auxiliary power recorded this year become the reference for the unit's whole life. CEMS and meters verified before commercial operation make those figures auditable.

What needs to be ready

    • 4.1 Operating certificate and CEMS link

      Apply for the operating certificate (SLO) after trial runs of emission controls and wastewater treatment, then connect CEMS so data reaches SISPEK every hour.

      According to Environment and Forestry Ministry Regulations 5/2021 and 13/2021

    • 4.2 Base-year greenhouse gas inventory

      Calculate tCO2e per MWh for each unit from fuel use and CEMS, including emissions from mining and hauling the fuel.

    • 4.3 Energy manager and first audit

      Energy providers using 6,000 tonnes of oil equivalent (TOE) a year or more must appoint an energy manager, audit at least once every three years and report annually.

      According to Energy Ministry Regulation 8/2025

Phase 5: Quota, fuel and rating move in the same direction.

Every heat-rate gain lowers emissions per MWh and saves fuel, while adding efficiency evidence for PROPER. Gas and geothermal plants have already shown that the top rating is within reach.

11 units of PLN Group won PROPER Gold in 2025, including combined-cycle and geothermal plants.

According to Fortune Indonesia, 2026

What needs to be ready

    • 5.1 Carbon quota as an asset

      Calculate each unit's surplus or deficit against its cap, then sell the surplus or cover the deficit with allowances or carbon units recorded in the national registry.

      According to Presidential Regulation 110/2025

    • 5.2 Co-firing you can prove

      Record the origin and type of biomass from every supplier so the emissions reduction claim passes verification.

      2.35 → 3.65 million tonnes of co-firing biomass, from 2025 delivery to the 2026 target

      According to PLN EPI via Kontan, 2026

    • 5.3 From Green towards Gold

      Build evidence on efficiency, coal ash use, outfall monitoring, biodiversity and SROI for fisher programmes.

Phase 6: The unit stops, the site keeps its value.

Early retirement is decided through a PLN study, and the cancelled plan for the Cirebon-1 coal plant in late 2025 shows how strict the criteria are. Existing land, substations and transmission make a coal site a candidate for solar, batteries or a combined-cycle gas plant.

According to Bisnis.com, 2025; Kontan, 2026

What needs to be ready

    • 6.1 Retirement study and funding

      Prepare the age, utilisation, emissions and funding data assessed in a PLN study of up to six months.

      US$3.4 billion of JETP funding realised by January 2026, out of US$21.8 billion committed

      According to Energy Ministry Regulation 10/2025; Listrik Indonesia, 2026

    • 6.2 Repowering and permit changes

      Solar and batteries on existing land change the technology and capacity, so the Environmental Approval is amended first. Close the ash pond and restore the land before the site is reused.

      According to Government Regulation 22/2021

    • 6.3 Workers and local suppliers

      Map permanent, contract and outsourced workers, plus suppliers that depend on the unit, then measure transition programmes with SROI.

The points that decide your unit's quota and rating.

From the jetty to the substation, every unit carries its own limits, meters and reports. Open them one by one.

Jetty, coal yard and biomass

Coal is unloaded from barges and biomass from trucks, then stockpiled before it enters the boiler bunkers.

  • Emissions
  • Water
  • Community
  • Safety

What you can manage

  • Log origin and tonnage for every fuel delivery
  • Suppress dust and monitor pile temperature
  • Route stockpile runoff to a settling pond

154 million tonnes of coal demand expected from power plants in 2026

Source: Listrik Indonesia, 2026

Boiler and turbine

Coal or a biomass blend raises steam for the turbine, the largest emission source and the driver of heat rate.

  • Emissions
  • Energy
  • Safety

What you can manage

  • Track daily heat rate and tCO2e per MWh
  • Meter fans, pumps and mills
  • Raise the co-firing share step by step

0.911–1.297 tCO2e per MWh, phase 1 caps for coal units

Source: ESDM, 2023

Emission controls and CEMS

Flue gas passes through FGD, NOx control and an ESP or baghouse, then is measured continuously at the stack.

  • Emissions
  • Community
  • Waste

What you can manage

  • Calibrate CEMS so daily data stays valid
  • Report CEMS outages within 48 hours
  • Reuse FGD gypsum and log it in the waste balance

550 → 200 mg/Nm³ SO2, older units against new units

Source: Regulation 15/2019

Cooling water and outfall

Sea or river water cools the condenser and returns warmer, together with treated effluent and blowdown.

  • Water
  • Biodiversity
  • Community
  • Energy

What you can manage

  • Monitor temperature and free chlorine at the compliance point
  • Monitor biota at the intake, reefs and mangroves
  • Fit variable speed drives on cooling pumps

Coal ash and ash pond

Fly ash from the ESP and bottom ash from the boiler collect in silos or an ash pond, then go to users.

  • Waste
  • Water
  • Emissions

What you can manage

  • Run regular TCLP tests and monitor ash-pond leachate
  • Sign volume contracts with cement and road users
  • Report the waste balance every six months

3.44 million tonnes of PLN coal ash used in 2025, 103% of output

Source: CNBC Indonesia, 2026

Geothermal wellpad and reinjection

Steam and brine from the wells are separated, drive a flash or ORC turbine, and the brine is reinjected into the reservoir.

  • Biodiversity
  • Emissions
  • Water
  • Community

What you can manage

  • Monitor ambient H2S at the nearest settlement
  • Reinject brine and monitor silica and arsenic
  • Calculate gCO2 per kWh including non-condensable gases

2,744 MW geothermal installed in 2025; the RUPTL adds 5.2 GW

Source: InvestorTrust, 2026; ESDM, 2025

Solar and battery storage

Solar arrays, inverters and batteries sit on open land or float on reservoirs, so land becomes the main issue.

  • Biodiversity
  • Community
  • Waste

What you can manage

  • Test agrivoltaic or floating options
  • Map habitats and wildlife corridors before fencing
  • Plan end-of-life panel management

1,494 MW solar installed in 2025; the RUPTL adds 17.1 GW

Source: InvestorTrust, 2026; ESDM, 2025

Substation, lines and older units

Power leaves through the substation and transmission lines, while older units are assessed for early retirement or repowering.

  • Community
  • Emissions
  • Biodiversity

What you can manage

  • Record compensation for land under high-voltage lines per plot
  • Include switchgear SF6 in the GHG inventory
  • Prepare older-unit data for retirement studies

Nearly 48,000 circuit-km of new transmission planned in the 2025–2034 RUPTL

Source: ESDM, 2025

Fishing villages and nearby communities

Fishers near the jetty and outfall, indigenous communities near wellpads and residents under the plume feel the effects first.

  • Community
  • Emissions
  • Biodiversity

What you can manage

  • Map fishing grounds and customary land
  • Log and answer every community complaint
  • Measure community programmes with SROI

No community conflict is a condition for Green PROPER candidates

Source: Regulation 7/2025

1 / 9

Typical facility illustration; not a specific site.

One source of data for quotas, PROPER and PSPK.

Without a single source, CEMS readings, meter data and the coal ash balance get copied into different spreadsheets for every report, and mismatches only surface at verification. Ailesh+ brings it together: CEMS and meters feed Energy+ and Carbon+ through IoT, coal ash goes to Waste+, mangroves and geothermal forest to Biodiv+, and fisher programmes to Social+. PROPER+ and ESG+ then build your reports from that same source.

Which phase is your generating unit in?

Tell us the phase. We'll map the data and documents that need to be ready.